Delta PathLine is an industrial laser projector designed for emergency exit indication and safety path marking. Operating on 5V DC with an integrated rechargeable battery, it provides up to 2 hours of backup operation during power loss. The system supports arrow or line projection and features an IP67 industrial enclosure for reliable use in harsh environments. Two operating modes — Safety Lighting Mode and Constant Operation Mode — enable flexible integration into emergency and continuous safety systems. Typical use cases include emergency exit indication, evacuation routing, power failure guidance, and industrial safety path marking.
| ● 520 | ● 638 |
| ≤200 | ≤300 |
| 2M | 2M |
| Diode | Diode |
| -10 ~ +60 | -10 ~ +65 |
5V DC
Li-ion 2100 mAh
~ 2 h
12h ~ 24h
Potential-free housing
4-pin M12 connector, Cable length: 2m
| ●PIN 3 Blue color (–) | ●PIN1 Brown color (+) |
Battery Enable Input: PIN 2 / PIN 4
*(A1) Arrow / *(B2) Line
*(PL) 60°, 90°, 110°
Fixed focus
*(А1) Projection
207 mm x 109,5 mm
8.15 in x 4.31 in
500
Anodized aluminum
IP67
| 2 | 3 | 4 | 5 | 6 |
| 380 | 580 | 780 | 980 | 1180 |
| 410 | 680 | 950 | 1220 | 1490 |
1. Safety Lighting Mode *(SM)
In Safety Lighting Mode, the laser remains OFF while input voltage is present. When the input
voltage is interrupted, the unit automatically switches to battery power and activates the
projection. The laser continues to operate until the input voltage is restored or the battery
capacity is depleted. When the input voltage returns, the laser turns OFF and the battery
charging process begins. The LED indicator displays the battery charging status.
2. Constant Operation Mode *(CM)
In Constant Operation Mode, the laser remains ON while input voltage is present. In the event of
power loss, the unit automatically switches to battery power without interruption of the
projection. The laser continues to operate until the input voltage is restored or the battery
capacity is depleted. When the input voltage returns, the laser remains ON, and the battery
charging process begins. The LED indicator displays the battery charging status
Important Notes:
*(Battery operation is enabled by shorting PIN 2 and PIN 4)
*(Do not apply external voltage to PIN 2 or PIN 4)
Power Supply Model: APV-12-5/ Input: 100~240V AC
LED indicator:
On: battery is charging;
Off: battery is charged or there is no input voltage;
Blinking: there is a problem with battery charging.